Easy Chester Ultimate

Easy Chester Ultimate combines AC and DC field checks with selected safety measurements. A guided touchscreen sequence and PDF report support consistent service work across a mixed charger fleet. Supports ISO 15118, DIN SPEC 70121 and CHAdeMO.

Open Easy Chester Ultimate field tester with its touchscreen and charging inlets

Overview

Easy Chester Ultimate is a portable EV charging station test device built for on-site commissioning, maintenance and troubleshooting. It simulates EV communication protocols per ISO 15118, DIN SPEC 70121 and CHAdeMO, with an integrated touchscreen and software for automatic test recording and report generation.

Easy Chester Ultimate covers both AC and DC work. If your scope is limited to AC wallboxes and charging stations, see Easy Chester Micro

Key Features

Handheld Portable

Suitcase with wheels and a handle, 15.7 kg

USB-C Powered

Draws max. 100 W from USB-C (20 V), a 12 V vehicle adapter, or a power bank with >100 W USB-C output

Supports both AC and DC testing systems

Supports AC / DC CCS / NACS / CHAdeMO

Supports test report generation

Capable of recording test results and generating test reports via software

Real-time Analysis

View test results in real-time

Built-in Test cases

Capable of creating and executing test profiles according to standard requirements

Field-Ready Design

Ruggedized design built for field use

Capabilities

Simulates EV communication per DIN 70121 and ISO 15118-2, -3 (optional) for DC, and IEC 61851-1, SAE J1772 for AC

Up to two inlets from CCS 1, CCS 2, NACS and CHAdeMO, with automatic detection of the charging procedure from the inserted plug

EV battery emulation on 400 V and 800 V technology, at approximately 330 V and 660 V

Optional fault simulation during charging — PE cable break, CP short circuit, PP short circuit and PP cable break

Optional DC isolation fault test during cable check — DC+ or DC- against PE using predefined resistance values from 47 kΩ to 780 kΩ

Optional AC isolation fault test — phases L1, L2 and L3 against PE through 2.5 kΩ, injected 5 seconds into the charging loop

Optional VDE/IEC electrical safety testing — six test cases covering isolation resistance (RISO), protective conductor resistance (RPE), fault current (tRCD), residual voltage (UOFF), loop impedance (ZS) and phase rotation

Automatic charging plug lock above 50 V (DC CCS, NACS, CHAdeMO) with an emergency unlock button, plus an automatic selftest at every power-on

Exports a PDF report with a PASSED or FAILED result, measured values, the charging communication steps, the station maximum charging power and its MAC-PLC address, with room for comments and a company logo

Maintenance package (ordered separately from the hardware): FOTA firmware updates, on-device remote support (hotspot required, during comemso office hours), GPS-derived location shown as an address and map in the report, and EVSE inspection photos attached to the report

Key Specifications

InletsUp to 2 inlets from CCS 1, CCS 2, NACS, CHAdeMO
Supported Charging StandardsCCS 1 and CCS 2 (DC, AC optional), CHAdeMO up to Version 2.0, NACS (DC)
Norm ConformityDC: DIN 70121, ISO 15118-2, -3 (optional), SAE J3400, SAE J1772 · AC: IEC 61851-1, SAE J1772 and ISO 15118-2, -3 (optional)
Display10.1 inch touchscreen (Ultimate UI)
Storage128 GB
Measuring RangeVoltage 0 – 1,000 V (±1 V resolution) · Current 0 – 10 A (±0.1 A), or 0 – 200 A with an external DC Load
Measuring AccuracyVoltage ±(1 V + 0.5 % of measured value) · Current ±0.5 A
DC Charging Capacity and Time2 kW / 6 A for up to 45 sec. Optional: with a Long Duration Unit 2 kW / 6 A up to 60 minutes; with a DC load 30 kW / 90 A up to 4 hours; with 2 DC loads 30 kW (60 kW in total) / 180 A up to 4 hours
DC Charging Technology400 V and 800 V technology — EV battery emulation with approx. 330 V and 660 V
LockLocks the charging plug at voltages > 50 V (DC CCS, NACS, CHAdeMO)
Power SupplyUSB-C (20 V), a 12 V USB-C vehicle adapter, or a power bank with >100 W USB-C output
Power ConsumptionMax. 100 W
Protection ClassPer IEC 60529: IP 66 (closed case), IP 43 (opened case)
Electrical Protection ClassClass II
Temperature Range-15 … +40 °C / +5 … +104 °F
Dimensions (W × H × D)60 × 33 × 40 cm / 24 × 13 × 16 inch
Weight15.7 kg / 34.6 lbs
ConnectivityFOTA, e-mail report delivery and remote support (hotspot required)

Demo Video

Interested in this product?

Contact our team for more information and a quotation.

Intellution

Authorized distributor of electronic testing, telecom, and measurement instruments from world-leading brands.

Address

Intellution Co., Ltd.
514/1 Soi Ramkhamhaeng 39 (Tepleela 1), Wangthonglang, Wangthonglang, Bangkok, Thailand 10310

Contact

Tel: 02-158-2558
Fax. 02-158-2559

Email: info@intellution.co.th

LINE: @intellution

Follow Us
© 2026 Intellution Co., Ltd. All rights reserved.